Company profile • Company
Iceotope
Seals each server and its coolant inside its own chassis, so there is no shared tank.
Direct answer
What this record says
Iceotope is a cooling supplier headquartered in Sheffield, United Kingdom. This record tracks no products of theirs and no deployments it is named in. Capabilities here are company-reported until independent evidence is attached. Last reviewed Aug. 9, 2026 against 1 source.
- Headquarters
- Sheffield, United Kingdom
- Ownership
- Private
- Architectures
- 2 architectures
- Evidence state
- Company reported
Company brief
What Iceotope does
Iceotope seals a small amount of fluid that does not conduct power inside each server case. Pipes inside the case guide it over processors, then memory, drives, power supplies, and other parts. A heat exchanger at the rear passes the heat to the building loop.
Iceotope calls this “direct to everything.” It differs from a cold plate that touches only a few hot chips and from one immersion tank shared by many servers. The design can remove server fans and keep dust and damp air away from the boards. Technicians still handle one server at a time.
Iceotope sells the idea for data centers, high-performance computing, phone networks, and edge sites. Some edge cabinets do not need building water. The tradeoff is that each server model needs its own sealed case, flow path, fluid choice, and service plan.
Buyers should ask which server makes and models are ready to ship, who owns the warranty, how a failed box is swapped, and whether it can be fixed on site. They must also know which coolant distribution unit or dry cooler is still needed. Check fluid fit, leak alarms, control links, warm-water limits, and any heat-reuse plan.
Iceotope reports more than 175 granted and pending patents plus power and water savings. These are company-reported facts and claims. Public material does not prove like-for-like cost, fleet uptime, or easy use across server brands, so buyers should ask for named sites and test records.
Use the connected product and deployment records to distinguish a stated capability from evidence that the company has delivered it.
Visit company website- Company type
- Liquid cooling specialist
- Headquarters
- Sheffield, United Kingdom
- Founded
- 2005
- Ownership
- Private
- Market listing
- Not publicly listed
- Evidence status
- Company reported
Capability matrix
What Iceotope can be shown to do
Stated capability, tracked products, and recorded projects are three different facts. A blank cell means this database has no record of it yet, not that the company does not do it.
| Architecture | Equipment categories | Tracked products | Recorded projects |
|---|---|---|---|
| Precision liquid cooling | — | — | — |
| Direct-to-chip liquid cooling | 2 | — | — |
Connected records
Cooling technologies
Precision liquid cooling
Each server is its own sealed, liquid-filled box, so there is no shared tank to fill or drain.
Direct-to-chip liquid cooling
A metal plate sits directly on each processor, and liquid pumped through it carries the heat out of the rack.
Connected records
Equipment categories
Cold plates
Small metal blocks that bolt onto a processor and carry its heat away in liquid.
Liquid cooling manifolds
The pipework inside a rack that splits coolant from one supply line out to every server, and collects it again.
Evidence ledger
Sources and evidence
Capabilities in this profile are traced to company materials. Treat them as supplier claims until a customer, filing, standard, or operating project confirms them.
- 01Iceotope — official website
Iceotope
Record information
- Record ID
- DCC / COMP / ICEOTOPE
- Record reviewed
- Aug. 9, 2026
- Record first published
- Aug. 9, 2026
- External sources
- 1
- Search visibility
- Withheld until the gaps below are closed
Required fields this record has not addressed yet, most important first:
- Tracked products
- Tracked deployments
Why this record is withheld from search:
- A company record needs at least one connected product or deployment.
Decide between
Comparable companies
Records covering the same cooling architecture, most-evidenced first.
Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.