Project database
Check what is operating, deploying, piloting, or merely planned, and see the public evidence that supports each status.
Use this section to decide
Is this system operating, being installed, piloting, or only announced?
What capacity, rack density, compute, and cooling architecture are public?
What evidence would be needed before treating the project as proven?
Featured records first, then the section's own editorial order.
A 24/7 New York-region data center received two Smardt AD120 chillers after an accelerated replacement program.
Supplier reported8 of 9 required fields addressedReviewed Oct. 4, 2026
DarkNX agreed to deploy Accelsius NeuCool across a planned 300 MW AI data-center campus in Ontario.
Supplier reported9 of 9 required fields addressedReviewed Aug. 9, 2026
The Government of Madhya Pradesh and Submer signed a memorandum of understanding covering up to 1 GW of liquid-cooled data center capacity.
Supplier reported9 of 9 required fields addressedReviewed Aug. 9, 2026
An unnamed Illinois data center installed Veolia pH control, acid feed, remote monitoring, and alarms for its cooling-tower water.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
Accelsius deployed its NeuCool IR80 two-phase direct-to-chip system at Equinix's DC15 Co-Innovation Facility in Ashburn.
Supplier reported9 of 9 required fields addressedReviewed Aug. 9, 2026
SoftBank, ZutaCore, and Foxconn demonstrated a rack-integrated two-phase direct-to-chip system using NVIDIA H200 GPUs.
Supplier reported9 of 9 required fields addressedReviewed Aug. 9, 2026
Stellium Data Centres, Circle B, and Submer assembled an OCP-aligned immersion-cooling proof of concept.
Supplier reported9 of 9 required fields addressedReviewed Aug. 9, 2026
Submer announced a 56 MW owned and operated liquid-cooled data center in Barcelona as a showcase for its facility platform.
Supplier reported9 of 9 required fields addressedReviewed Aug. 9, 2026
An American data center operator, not named, ordered 300 MW worth of LiquidStack's one-megawatt coolant distribution units for several AI sites.
Supplier reported9 of 9 required fields addressedReviewed Aug. 9, 2026
Novva Data Centers replaced cooling controllers at its Colorado Springs facility with Siemens Desigo PXC controls while maintaining live operation.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
An unnamed 160 MW high-performance-computing customer adopted a chillerless BAC HXV hybrid-cooler design.
Supplier reported8 of 9 required fields addressedReviewed Oct. 4, 2026
Shell runs a 1.2 MW Penguin Solutions high-performance computing cluster in GRC immersion tanks at the Skybox Houston One facility.
Supplier reported9 of 9 required fields addressedReviewed Aug. 9, 2026
Castrol installed working Submer immersion systems and Hypertec server hardware at its Pangbourne headquarters for joint fluid and system testing.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
Sixteen TORRAVAL CTFP 2436 open-circuit cooling towers serve a Barcelona data-processing center designed for 20 MW and expansion to 40 MW.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
NorthC operates a Grundfos MIXIT-controlled water loop for chip-level cooling at its High Tech Campus Eindhoven data center.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
The Texas Advanced Computing Center uses GRC ICEraQ Series 10 immersion systems for part of its Lonestar6 supercomputer.
Supplier reported9 of 9 required fields addressedReviewed Aug. 9, 2026
Fujitsu integrated Stäubli CGD quick-release couplings into Fugaku's liquid-cooled blade system at RIKEN in Kobe.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
DataBank's ATL1 facility uses ColdLogik rear-door cooling for Georgia Tech high-performance computing loads in Atlanta.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
Four Güntner V-shape VARIO dry coolers reject heat from a two-phase immersion data center in Zhangjiakou, China.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
Armstrong supplied factory-integrated variable-primary chilled-water plant rooms for the second phase of Digital Realty's HKG10 data center.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
Infosys uses multiple SWEP B649 heat exchangers to isolate cooling-tower water from the clean data-center cooling loop in Hyderabad.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
The University of Cambridge uses ColdLogik rear-door heat exchangers in its West Cambridge Data Centre for high-density research computing.
Supplier reported9 of 9 required fields addressedReviewed Oct. 4, 2026
NREL's Energy Systems Integration Facility uses Bell & Gossett pumps in a warm-water supercomputing loop that captures heat for building reuse.
Operating evidence9 of 9 required fields addressedReviewed Oct. 4, 2026