Operating supercomputing deployment • Deployment
TACC Lonestar6 immersion cooling
The Texas Advanced Computing Center uses GRC ICEraQ Series 10 immersion systems for part of its Lonestar6 supercomputer.
Direct answer
What this record says
TACC Lonestar6 immersion cooling is an operating cooling deployment in Austin, Texas, United States, operated by Texas Advanced Computing Center. It is recorded at 280 kW immersed system. It was announced Jan. 31, 2022. Last reviewed Aug. 9, 2026 against 1 source.
- Operator
- Texas Advanced Computing Center
- Stage
- Operating
- Capacity
- 280 kW immersed system
- Rack density
- Not disclosed
Project brief
What is publicly known
Status: operating. GRC reported in January 2022 that the Texas Advanced Computing Center had deployed 280 kilowatts of ICEraQ Series 10 single-phase immersion capacity for part of the Lonestar6 supercomputer. The system cools Dell C6525 servers using AMD EPYC processors.
This is a named operator, system, server platform, location, and installed load, which is materially stronger than an order or memorandum. The public evidence is still a supplier case study. We have not been given a Texas Advanced Computing Center acceptance report, operating log, or independent energy audit.
The cooling design places servers in a dielectric liquid that remains in one phase. Heat moves from the bath through a heat exchanger to facility water. GRC says removing server fans reduced server power by about ten percent and that cooling achieved a partial power usage effectiveness of 1.02.
Partial power usage effectiveness describes only the measured subsystem, not every electrical load in the building. Those values are useful directional evidence, but they need a stated test boundary, weather period, and workload before they can support a facility-wide comparison. Unknowns include water supply and return temperatures, tank count, utilization, maintenance history, fluid testing, failure events, and whether the original 280 kilowatts remain in service.
The record would become stronger with operator-published performance data, a recent operating update, measured energy over a full season, or details on server service and fluid condition after several years. Evidence of expansion would justify a higher capacity. Evidence that Lonestar6 has been decommissioned or the tanks removed would change the status to retired, a state the current schema does not yet express.
Until then, operating is the best-supported label, with supplier-reported performance clearly qualified.
Status is labeled from public evidence. Supplier orders, MoUs, pilots, projects under delivery, and operating sites are not counted as equivalent.
- Status
- Operator
- Texas Advanced Computing Center
- Location
- Austin, Texas, United States
- Capacity
- 280 kW immersed system
- Rack density
- Not disclosed
- Compute
- Dell C6525 servers with AMD EPYC CPUs
- Announced
- Jan 31, 2022
Connected records
Companies involved
GRC
One of the longest-established immersion cooling companies, supplying the tanks, the fluid, and the controls together.
Dell Technologies
Ships factory-integrated PowerEdge racks with PowerCool cold plates, manifolds, distribution units, and rear-door options.
Connected records
Cooling architecture
Connected records
Equipment chain
Immersion cooling tanks
The tank itself, plus everything needed to run submerged servers: power, networking, lifting gear, and fluid handling.
Liquid cooling fluids
The fluid itself: water, glycol mixtures, oils, and engineered fluids that do not conduct electricity.
Heat exchangers
The component that passes heat from one loop of fluid to another without the two ever touching.
Evidence ledger
Sources and evidence
The links below show where the factual claims came from. Supplier specifications remain supplier-reported unless the record names independent operating evidence.
- 01GRC cools Lonestar6 supercomputer
GRC · Jan 31, 2022
Record information
- Record ID
- DCC / DEPL / TACC-LONESTA
- Record reviewed
- Aug. 9, 2026
- Newest source published
- Jan. 31, 2022
- Record first published
- Aug. 9, 2026
- External sources
- 1
- Search visibility
- Offered to search engines
This field was researched and is not published by the party who would know:
- Rack density
Decide between
Comparable deployments
Records covering the same cooling architecture, most-evidenced first.
Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.