Submer Barcelona AI data center
Submer announced a 56 MW owned and operated liquid-cooled data center in Barcelona as a showcase for its facility platform.
Direct answer
What this record says
Submer Barcelona AI data center is a planned cooling deployment in Barcelona, Spain, operated by Submer. It is recorded at 56 MW. It was announced Feb. 28, 2025. Last reviewed Aug. 9, 2026 against 1 source.
- Operator
- Submer
- Stage
- Planned
- Capacity
- 56 MW
- Rack density
- 150 kW+ per rack or tank (design target)
Project brief
What is publicly known
Status: planned. Submer's February 2025 announcement says the company is developing a 56 megawatt data center in Barcelona that it intends to own and operate. The same release launched new design, construction, operations, and artificial-intelligence-as-a-service business units.
It presents Barcelona as the first phase of a wider European program. This is useful evidence of strategy and design intent, but it is not a construction notice or an operating record. What is known is the proposed performance envelope.
Submer says the site would support at least 150 kilowatts per rack or immersion tank. It also says the facility would use liquid cooling and consume no water in normal operation. The company names direct liquid cooling and immersion as capabilities, but it does not allocate the 56 megawatts between them or identify server, plant, or heat-rejection equipment.
Cooling matters here because a dense Barcelona site must carry peak summer conditions while meeting the claimed water target. A closed loop can avoid routine water consumption, but it still needs a credible way to reject heat on hot days. The announcement does not disclose that design, its energy use, or the conditions behind the zero-water claim.
Also unknown are the site address, land and grid rights, planning approval, financing, construction partner, customer commitments, opening date, and staged capacity. We would change the status to deploying when permits, site work, utility agreements, financing, or equipment orders are independently visible. An operator commissioning notice and measured rack, energy, and water data would support operating status.
If later filings reduce the capacity or change the ownership model, this record should follow those harder facts rather than the original headline.
Status is labeled from public evidence. Supplier orders, MoUs, pilots, projects under delivery, and operating sites are not counted as equivalent.
- Status
- Planned
- Operator
- Submer
- Location
- Barcelona, Spain
- Capacity
- 56 MW
- Rack density
- 150 kW+ per rack or tank (design target)
- Compute
- AI infrastructure
- Announced
- Feb 28, 2025
Connected records
Companies involved
Connected records
Cooling architecture
Direct-to-chip liquid cooling
A metal plate sits directly on each processor, and liquid pumped through it carries the heat out of the rack.
Single-phase immersion cooling
Whole servers sit in a tank of oil-like fluid that does not conduct electricity. The fluid warms up and carries the heat away without ever boiling.
Hybrid air and liquid cooling
Liquid takes the heat off the processors while air handles the rest of the rack. Almost every liquid-cooled hall works this way.
Connected records
Equipment chain
Coolant distribution units
The unit that stands between the building's water and the servers, controlling how much coolant flows, how cold it is, and how clean it stays.
Immersion cooling tanks
The tank itself, plus everything needed to run submerged servers: power, networking, lifting gear, and fluid handling.
Evidence ledger
Sources and evidence
The links below show where the factual claims came from. Supplier specifications remain supplier-reported unless the record names independent operating evidence.
- 01Submer expands into data-center design and AI infrastructure services
Submer · Feb 28, 2025
Record information
- Record ID
- DCC / DEPL / SUBMER-BARCE
- Record reviewed
- Aug. 9, 2026
- Newest source published
- Feb. 28, 2025
- Record first published
- Aug. 9, 2026
- External sources
- 1
- Search visibility
- Offered to search engines
Decide between
Comparable deployments
Records covering the same cooling architecture, most-evidenced first.
Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.