Co-innovation deployment • Deployment
Equinix Ashburn NeuCool deployment
Accelsius deployed its NeuCool IR80 two-phase direct-to-chip system at Equinix's DC15 Co-Innovation Facility in Ashburn.
Direct answer
What this record says
Equinix Ashburn NeuCool deployment is an operating cooling deployment in Ashburn, Virginia, United States, operated by Equinix. It is recorded at IR80 demonstration system. It was announced July 15, 2025. Last reviewed Aug. 9, 2026 against 1 source.
- Operator
- Equinix
- Stage
- Operating
- Capacity
- IR80 demonstration system
- Rack density
- Not disclosed
Project brief
What is publicly known
Status: operating as a demonstration, not as a production fleet deployment. Accelsius announced in July 2025 that its NeuCool IR80 would be installed during the third quarter at Equinix's Co-Innovation Facility inside the DC15 International Business Exchange data center in Ashburn. The facility exists to let Equinix and its customers test new infrastructure.
That setting supports the operating label for a validation system, but it does not show that Equinix has adopted NeuCool across customer halls. The cited evidence comes from Accelsius. It includes an Equinix statement about the role of the facility, but no separate Equinix commissioning report or measured test dataset.
The system is relevant because it puts two-phase direct-to-chip cooling where buyers can examine it. A dielectric refrigerant boils at cold plates on the chips, then condenses and recirculates. Accelsius says this allows inlet water six to eight degrees Celsius warmer than other technologies.
If that holds at the required server load, Ashburn's climate could provide more hours of heat rejection without compressors. The public release does not disclose the installed thermal capacity, rack density, server model, facility-water temperatures, test duration, availability, pump energy, or residual air load. It also does not publish customer results or failure tests.
Evidence that would strengthen this record includes Equinix confirmation that commissioning finished, a test protocol, measured energy and temperature data, or continued use beyond demonstrations. A production customer deployment in DC15 would be a separate and stronger milestone. Evidence that the installation was delayed, removed, or never commissioned would move this record back from operating to planned or retired.
Status is labeled from public evidence. Supplier orders, MoUs, pilots, projects under delivery, and operating sites are not counted as equivalent.
- Status
- Operator
- Equinix
- Location
- Ashburn, Virginia, United States
- Capacity
- IR80 demonstration system
- Rack density
- Not disclosed
- Compute
- Co-innovation and customer validation
- Announced
- Jul 15, 2025
Connected records
Companies involved
Connected records
Cooling architecture
Connected records
Equipment chain
Cold plates
Small metal blocks that bolt onto a processor and carry its heat away in liquid.
Coolant distribution units
The unit that stands between the building's water and the servers, controlling how much coolant flows, how cold it is, and how clean it stays.
Evidence ledger
Sources and evidence
The links below show where the factual claims came from. Supplier specifications remain supplier-reported unless the record names independent operating evidence.
- 01Accelsius brings NeuCool to Equinix's Co-Innovation Facility in Ashburn
Accelsius · Jul 15, 2025
Record information
- Record ID
- DCC / DEPL / EQUINIX-ASHB
- Record reviewed
- Aug. 9, 2026
- Newest source published
- July 15, 2025
- Record first published
- Aug. 9, 2026
- External sources
- 1
- Search visibility
- Offered to search engines
This field was researched and is not published by the party who would know:
- Rack density
Decide between
Comparable deployments
Records covering the same cooling architecture, most-evidenced first.
Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.
Latest coverage