Company profile • Company
Munters
Specializes in cooling air with evaporating water, which trades electricity for water use.
Direct answer
What this record says
Munters is a cooling supplier headquartered in Kista, Sweden. This record tracks no products of theirs and no deployments it is named in. Capabilities here are company-reported until independent evidence is attached. Last reviewed Aug. 9, 2026 against 1 source.
- Headquarters
- Kista, Sweden
- Ownership
- Public
- Architectures
- 2 architectures
- Evidence state
- Company reported
Company brief
What Munters does
Munters supplies air-side thermal equipment for data centers, with particular depth in evaporative and indirect evaporative cooling, air handling, and heat exchange. Instead of relying on compressor refrigeration for every hour, these systems use evaporation to cool an air stream or heat exchanger when weather permits. That can reduce electrical demand in dry conditions, but it moves part of the operating burden to water supply, treatment, discharge, and hygiene.
Indirect designs keep the wetted air separate from the data hall; direct designs have a closer relationship with room humidity and outside-air quality. Munters therefore belongs at the room and heat-rejection stages of the chain, not at the processor cold plate or rack manifold. It can serve conventional air-cooled halls and the residual air load in hybrid halls where liquid removes only processor heat.
Buyers should model a full year of local wet-bulb conditions rather than compare a single design-point efficiency. They also need maximum-day water use, water quality limits, filtration, plume and legionella controls where relevant, fan redundancy, turndown, sound, controls integration, maintenance access, and a fallback mode for humid or water-constrained periods. Munters' website confirms a data-center cooling focus, but the homepage provides little product-level evidence.
Technology scope and any savings claims are company-reported; public material reviewed for this profile does not establish project pricing, independent fleet performance, or suitability for a specific climate.
Use the connected product and deployment records to distinguish a stated capability from evidence that the company has delivered it.
Visit company website- Company type
- Cooling platform vendor
- Headquarters
- Kista, Sweden
- Founded
- 1955
- Ownership
- Public
- Market listing
- STO: MTRS
- Evidence status
- Company reported
Capability matrix
What Munters can be shown to do
Stated capability, tracked products, and recorded projects are three different facts. A blank cell means this database has no record of it yet, not that the company does not do it.
| Architecture | Equipment categories | Tracked products | Recorded projects |
|---|---|---|---|
| Evaporative cooling | 1 | — | — |
| Hybrid air and liquid cooling | 1 | — | — |
Connected records
Cooling technologies
Evaporative cooling
Evaporating water cools the air, the same way sweat cools skin. It saves electricity and spends water.
Hybrid air and liquid cooling
Liquid takes the heat off the processors while air handles the rest of the rack. Almost every liquid-cooled hall works this way.
Connected records
Equipment categories
Evidence ledger
Sources and evidence
Capabilities in this profile are traced to company materials. Treat them as supplier claims until a customer, filing, standard, or operating project confirms them.
- 01Munters — official website
Munters
Record information
- Record ID
- DCC / COMP / MUNTERS
- Record reviewed
- Aug. 9, 2026
- Record first published
- Aug. 9, 2026
- External sources
- 1
- Search visibility
- Withheld until the gaps below are closed
Required fields this record has not addressed yet, most important first:
- Tracked products
- Tracked deployments
Why this record is withheld from search:
- A company record needs at least one connected product or deployment.
Decide between
Comparable companies
Records covering the same cooling architecture, most-evidenced first.
Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.