Company profile Company

Chilldyne

Runs its coolant below atmospheric pressure, so a damaged line draws air in instead of leaking water out.

negative pressuredirect-to-chipCDUHPC

Direct answer

What this record says

Chilldyne is a cooling supplier headquartered in Carlsbad, California, United States. This record tracks no products of theirs and no deployments it is named in. Capabilities here are company-reported until independent evidence is attached. Last reviewed Aug. 9, 2026 against 1 source.

1 sourceReviewed Aug. 9, 2026
Headquarters
Carlsbad, California, United States
Ownership
Daikin Applied
Architectures
1 architecture
Evidence state
Company reported

Company brief

What Chilldyne does

Chilldyne supplies a direct-to-chip water loop that operates below atmospheric pressure. Its pumps pull coolant through cold plates and manifolds, so a breach is intended to draw air into the circuit instead of pushing water onto electronics. The company packages the coolant distribution unit, rack manifold, cold plates, and Cool-Flo monitoring software as one system.

That pressure strategy is the core distinction; it addresses leak consequence differently from positive-pressure loops, while still using familiar single-phase water cooling at the processor. Chilldyne reports operating graphics-processing-unit clusters since 2014 and cites installations at Sandia and Cirrascale. Daikin Applied acquired the company in November 2025, linking its rack-side system to Daikin chillers, DDC Solutions cabinets, and a broader service organization.

Buyers still need to examine how the loop detects and removes ingested air, how much vacuum margin remains at the most distant cold plate, and what happens during pump or power failure. They should also verify server approvals, cold-plate coverage, residual air load, water chemistry, pressure drop, redundancy, controls links, local parts, and who owns the server warranty. The negative-pressure principle does not eliminate every possible spill during filling, draining, or service.

Acquisition details, deployment history, and leak-performance claims here are company-reported by Chilldyne and Daikin Applied; buyers should request site references and witnessed failure testing.

Use the connected product and deployment records to distinguish a stated capability from evidence that the company has delivered it.

Visit company website
Company type
Liquid cooling specialist
Headquarters
Carlsbad, California, United States
Founded
Not disclosed
Ownership
Daikin Applied
Market listing
Not publicly listed
Evidence status
Company reported

Capability matrix

What Chilldyne can be shown to do

Stated capability, tracked products, and recorded projects are three different facts. A blank cell means this database has no record of it yet, not that the company does not do it.

ArchitectureEquipment categoriesTracked productsRecorded projects
Direct-to-chip liquid cooling3

Connected records

Cooling technologies

View all cooling technologies

Connected records

Equipment categories

View all equipment categories

Evidence ledger

Sources and evidence

Capabilities in this profile are traced to company materials. Treat them as supplier claims until a customer, filing, standard, or operating project confirms them.

  1. 01
Record information
Record ID
DCC / COMP / CHILLDYNE
Record reviewed
Aug. 9, 2026
Record first published
Aug. 9, 2026
External sources
1
Search visibility
Withheld until the gaps below are closed

Required fields this record has not addressed yet, most important first:

  • Tracked products
  • Tracked deployments
  • Founded

Why this record is withheld from search:

  • A company record needs at least one connected product or deployment.

Decide between

Comparable companies

Records covering the same cooling architecture, most-evidenced first.

View all companies

Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.