| Record | Stage | Operator | Location | Architecture | Suppliers | Capacity | Rack density | Compute | Announced | Fields addressed | Evidence | Sources | Reviewed | Comparison |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Smardt New York-region data-center chiller replacement | Operating | Not publicly disclosed | New York region, United States | Hybrid Cooling | 1 | Two AD120 chillers; thermal capacity not publicly disclosed | Not publicly disclosed | Critical IT infrastructure; platform not publicly disclosed | 2026-10-04 | 8/9 | Supplier reported | 1 |
| Illinois data-center cooling-water treatment retrofit | Operating | Undisclosed data-center operator | Illinois, United States; city not disclosed | Evaporative Cooling, Hybrid Cooling | 1 | Not disclosed | Not disclosed | Not disclosed | 2025-07-23 | 9/9 | Supplier reported | 1 |
|---|
| Equinix Ashburn NeuCool deployment | Operating | Equinix | Ashburn, Virginia, United States | Two Phase Direct To Chip | 1 | IR80 demonstration system | Not disclosed | Co-innovation and customer validation | 2025-07-15 | 9/9 | Supplier reported | 1 |
|---|
| Novva Colorado Springs cooling-controls retrofit | Operating | Novva Data Centers | Colorado Springs, Colorado, United States | Hybrid Cooling | 1 | Four chillers and two chiller plants; IT capacity not disclosed | Not disclosed | Colocation workloads; server platform not disclosed | 2024-07-22 | 9/9 | Supplier reported | 2 |
|---|
| BAC 160 MW HPC HXV cooling project | Operating | Not publicly disclosed | Not publicly disclosed | Hybrid Cooling, Dry Cooling +1 | 1 | 160 MW customer operating power | Not publicly disclosed | High-performance computing | 2024-04-25 | 8/9 | Supplier reported | 2 |
|---|
| Shell Skybox Houston immersion cluster | Operating | Shell | Katy, Texas, United States | Single Phase Immersion | 1 | 1.2 MW | Up to 100 kW per 42U rack with warm water, company reported | Penguin Solutions high-performance computing cluster with AMD processors | 2024-01-01 | 9/9 | Supplier reported | 1 |
|---|
| MITA Barcelona data-processing center cooling towers | Operating | Not publicly disclosed; described as an international IT company | Barcelona, Catalonia, Spain | Evaporative Cooling | 1 | 20 MW required, expandable to 40 MW, plus 5 MW emergency supply; source does not define the capacity boundary | Not publicly disclosed | Data-processing workloads; platform not publicly disclosed | 2023-01-01 | 9/9 | Supplier reported | 1 |
|---|
| NorthC Eindhoven MIXIT chip-cooling loop | Operating | NorthC Datacenters | Eindhoven, North Brabant, Netherlands | Direct To Chip, Heat Reuse +1 | 1 | Not publicly disclosed | Not publicly disclosed | High-performance computing and chip-level liquid-cooled workloads | 2022-06-01 | 9/9 | Supplier reported | 2 |
|---|
| TACC Lonestar6 immersion cooling | Operating | Texas Advanced Computing Center | Austin, Texas, United States | Single Phase Immersion | 2 | 280 kW immersed system | Not disclosed | Dell C6525 servers with AMD EPYC CPUs | 2022-01-31 | 9/9 | Supplier reported | 1 |
|---|
| Fugaku Stäubli CGD cooling connections | Operating | RIKEN | Kobe, Hyogo, Japan | Direct To Chip | 1 | 400 racks; compute power capacity not stated in cited cooling source | Not publicly disclosed | Fujitsu Fugaku supercomputer with more than 150,000 processors reported by Stäubli | 2021-03-09 | 9/9 | Supplier reported | 2 |
|---|
| DataBank ATL1 ColdLogik rear-door cooling | Operating | DataBank | Atlanta, Georgia, United States | Rear Door Heat Exchangers, Hybrid Cooling | 1 | ATL1 facility: 7.1 MW current critical IT load; ColdLogik subsystem capacity not publicly disclosed | 50 kW per rack at 73°F water reported for the ColdLogik design | Georgia Tech high-performance computing and research workloads | 2019-11-28 | 9/9 | Supplier reported | 2 |
|---|
| Güntner Zhangjiakou immersion-cooling heat rejection | Operating | Not publicly disclosed; described as a major Chinese e-commerce company | Zhangjiakou, Hebei, China | Two Phase Immersion, Dry Cooling +1 | 1 | 1,060 kW aggregate dry-cooler capacity | Not publicly disclosed | Cloud computing in two-phase immersion; hardware not publicly disclosed | 2017-01-01 | 9/9 | Supplier reported | 1 |
|---|
| Digital Realty HKG10 Armstrong chilled-water plant rooms | Operating | Digital Realty | Tseung Kwan O, Hong Kong | Hybrid Cooling | 1 | Facility cooling capacity not publicly disclosed | Not publicly disclosed | Colocation workloads | 2016-09-19 | 9/9 | Supplier reported | 2 |
|---|
| Infosys Hyderabad data-center heat exchangers | Operating | Infosys | Hyderabad, Telangana, India | Hybrid Cooling, Dry Cooling | 2 | Multiple B649 units at 350 m³/h each; thermal capacity not publicly disclosed | Not publicly disclosed | Enterprise data-center workloads; platform not publicly disclosed | 2016-01-01 | 9/9 | Supplier reported | 1 |
|---|
| West Cambridge Data Centre ColdLogik cooling | Operating | University of Cambridge | Cambridge, England, United Kingdom | Rear Door Heat Exchangers, Hybrid Cooling | 1 | 1.2 MW data-hall capacity reported by USystems | Up to 44 kW per cabinet reported by USystems | University research computing and administrative services | 2015-03-19 | 9/9 | Supplier reported | 2 |
|---|
| NREL ESIF warm-water cooling loop | Operating | National Renewable Energy Laboratory | Golden, Colorado, United States | Direct To Chip, Heat Reuse +1 | 2 | IT capacity not disclosed in the cited Xylem case | Not disclosed | Warm-water liquid-cooled high-performance computing systems | 2012-01-01 | 9/9 | Operating evidence | 2 |
|---|