Multi-rack cooling unit Product

Accelsius MR250

A 250 kW in-row, multi-rack unit for the NeuCool two-phase direct-to-chip platform.

CDU250 kWtwo phasemulti-rack

Direct answer

What this record says

Accelsius MR250 is a cooling product from Accelsius. It is rated at 250 kW, with no duty point stated alongside the figure. Its lifecycle status is available. Last reviewed Aug. 9, 2026 against 1 source.

1 sourceReviewed Aug. 9, 2026
Manufacturer
Accelsius
Rated capacity
250 kWNo duty point stated
Total flow
Not recorded
Status
Available

Product brief

What the record shows

The MR250 is Accelsius's 250 kW in-row distribution and heat-rejection unit for several racks using the NeuCool two-phase direct-to-chip loop. Dielectric refrigerant boils at processor plates, carries heat as vapor, and is condensed and recirculated by the shared unit. The arrangement moves pumps and controls out of each rack and can reduce repeated hardware, but it also creates a shared operating boundary.

Capacity must be allocated across all attached racks, and isolation matters when one rack or branch needs service. Accelsius supplied an MR250 for system-level testing in the United States Department of Energy's Advanced Research Projects Agency–Energy COOLERCHIPS program. The company also reported a full 250 kW rack demonstration with 40°C facility water, but that broader platform test should not be read as a complete MR250 acceptance test for every layout.

The cited announcement planned general availability for late 2025; it does not provide current lead time or installed-base data. Public material does not disclose dimensions, refrigerant charge, facility connection sizes, pump curves, electrical input, sound, pressure limits, or capacity after a pump, power, or controller failure. Ask how many racks and plate branches the quoted duty assumes, which server configurations are approved, and how residual air heat is handled.

Procurement should require duty-point data, refrigerant safety and recovery procedures, alarm and control interfaces, branch isolation, factory testing, commissioning scope, spares, and service coverage.

Capacity figures are supplier-reported unless the source says otherwise. Compare products at the same temperatures, flow, pressure, and redundancy state.

Specification4 reviewed claims
Rated capacity
250 kWSupplier reported · Accelsius · reviewed 2026-09-04
Format
In-row, multi-rackSupplier reported · Accelsius · reviewed 2026-09-04
Cooling architecture
Two phaseSupplier reported · Accelsius · reviewed 2026-09-04
Lifecycle
AvailableSupplier reported · Accelsius · reviewed 2026-09-04
Program
ARPA-E COOLERCHIPS testingSupplier wording, not yet normalized
Manufacturer
Accelsius

Connected records

Compatible architecture

Connected records

Equipment category

Evidence ledger

Sources and evidence

The links below show where the factual claims came from. Supplier specifications remain supplier-reported unless the record names independent operating evidence.

  1. 01
Record information
Record ID
DCC / PROD / ACCELSIUS-MR
Record reviewed
Aug. 9, 2026
Latest claim reviewed
Sept. 4, 2026
Newest source published
July 29, 2025
Record first published
Aug. 9, 2026
External sources
1
Search visibility
Offered to search engines

Required fields this record has not addressed yet, most important first:

  • Rating conditions
  • Total coolant flow
  • Facility-water supply and return
  • Technology-water temperature
  • Public deployment evidence
  • Pressure or head
  • Redundancy
  • Fluid compatibility
  • Dimensions

Decide between

Comparable products

The same equipment category from other manufacturers, most-evidenced first.

View all products

Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.

Direct answers

Frequently asked questions

Direct answers drawn from the record, its comparison fields, and the evidence linked below.

What is the Accelsius MR250?

The MR250 is Accelsius's 250 kW in-row distribution and heat-rejection unit for several racks using the NeuCool two-phase direct-to-chip loop. Dielectric refrigerant boils at processor plates, carries heat as vapor, and is condensed and recirculated by the shared unit. The arrangement moves pumps and controls out of each rack and can reduce repeated hardware, but it also creates a shared operating boundary. Capacity must be allocated across all attached racks, and isolation matters when one rack or branch needs service. Accelsius supplied an MR250 for system-level testing in the United States Department of Energy's Advanced Research Projects Agency–Energy COOLERCHIPS program. The company also reported a full 250 kW rack demonstration with 40°C facility water, but that broader platform test should not be read as a complete MR250 acceptance test for every layout. The cited announcement planned general availability for late 2025; it does not provide current lead time or installed-base data. Public material does not disclose dimensions, refrigerant charge, facility connection sizes, pump curves, electrical input, sound, pressure limits, or capacity after a pump, power, or controller failure. Ask how many racks and plate branches the quoted duty assumes, which server configurations are approved, and how residual air heat is handled. Procurement should require duty-point data, refrigerant safety and recovery procedures, alarm and control interfaces, branch isolation, factory testing, commissioning scope, spares, and service coverage.

Who makes the Accelsius MR250?

Accelsius makes it. We file it under coolant distribution units, and its status is available.

What are the key specifications for the Accelsius MR250?

Format: In-row, multi-rack; Program: ARPA-E COOLERCHIPS testing; Capacity: 250 kW. These figures come from the supplier. Before comparing two products, restate both at your own water temperatures, flow, pressure, and redundancy, because a rating measured under favorable conditions will not hold on site.