Coolant distribution unit Product

DCX Enterprise ECDU 1380/2600

A rack-format coolant distribution unit stated at 1.38 to 2.6 MW, with a single pump reaching 3,333 liters per minute.

CDU2.6 MWwarm waterOCP rack

Direct answer

What this record says

DCX Enterprise ECDU 1380/2600 is a cooling product from DCX Liquid Cooling. The supplier publishes a capacity of 1.38 MW to 2.6 MW, not yet reviewed as a normalized claim. Its lifecycle status is available. Last reviewed Sept. 4, 2026 against 1 source.

1 sourceReviewed Sept. 4, 2026
Manufacturer
DCX Liquid Cooling
Rated capacity
1.38 MW to 2.6 MWNo duty point stated
Total flow
Up to 3,333 liters per minute, single pump
Status
Available

Product brief

What the record shows

DCX launched the ECDU family in March 2026 as three models spanning 600 kW to 2.6 MW. This record covers the Enterprise model, which DCX states at 1.38 to 2.6 megawatts of what it calls real cooling capacity, meaning capacity at secondary-loop conditions rather than a laboratory best case. A single pump configuration reaches 3,333 liters per minute.

The unit accepts supply water up to 45 degrees Celsius continuously, which keeps a chiller off the critical path in many climates, and uses an AT3 class heat exchanger with a high number of transfer units. It fits a 600 or 800 mm wide footprint at standard rack depth, so it sits in a row without a bespoke plinth. Pumps, power supplies and controls are N+1 as standard; redundant heat exchangers and redundant temperature, pressure and flow sensors are a separate mission-critical variant.

DCX does not publish the approach temperature that the stated capacity assumes, the pressure drop across the unit, the electrical load, or the secondary fluid the rating uses. Those four gaps make the megawatt figure hard to compare with a rival quoted at a named approach. Ask for a selection at the site's own facility-water temperature and approach, the hydraulic curve, and which parts can be exchanged while the row stays live.

Capacity figures are supplier-reported unless the source says otherwise. Compare products at the same temperatures, flow, pressure, and redundancy state.

SpecificationSupplier-stated
Footprint
600 mm or 800 mm wide, standard rack depthSupplier wording, not yet normalized
Redundancy
N+1 pumps, power supplies and controlsSupplier wording, not yet normalized
Coolant flow
Up to 3,333 liters per minute, single pumpSupplier wording, not yet normalized
Rated capacity
1.38 MW to 2.6 MWSupplier wording, not yet normalized
Supply temperature
Up to 45°C continuousSupplier wording, not yet normalized
Heat exchanger class
AT3, high number of transfer unitsSupplier wording, not yet normalized
Manufacturer
DCX Liquid Cooling

Connected records

Compatible architecture

Connected records

Equipment category

Evidence ledger

Sources and evidence

The links below show where the factual claims came from. Supplier specifications remain supplier-reported unless the record names independent operating evidence.

  1. 01
Record information
Record ID
DCC / PROD / DCX-ECDU-138
Record reviewed
Sept. 4, 2026
Newest source published
March 11, 2026
Record first published
Sept. 4, 2026
External sources
1
Search visibility
Offered to search engines

Required fields this record has not addressed yet, most important first:

  • Rating conditions
  • Facility-water supply and return
  • Public deployment evidence
  • Pressure or head
  • Deployment format

Decide between

Comparable products

The same equipment category from other manufacturers, most-evidenced first.

View all products

Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.

Direct answers

Frequently asked questions

Direct answers drawn from the record, its comparison fields, and the evidence linked below.

What is the DCX Enterprise ECDU 1380/2600?

DCX launched the ECDU family in March 2026 as three models spanning 600 kW to 2.6 MW. This record covers the Enterprise model, which DCX states at 1.38 to 2.6 megawatts of what it calls real cooling capacity, meaning capacity at secondary-loop conditions rather than a laboratory best case. A single pump configuration reaches 3,333 liters per minute. The unit accepts supply water up to 45 degrees Celsius continuously, which keeps a chiller off the critical path in many climates, and uses an AT3 class heat exchanger with a high number of transfer units. It fits a 600 or 800 mm wide footprint at standard rack depth, so it sits in a row without a bespoke plinth. Pumps, power supplies and controls are N+1 as standard; redundant heat exchangers and redundant temperature, pressure and flow sensors are a separate mission-critical variant. DCX does not publish the approach temperature that the stated capacity assumes, the pressure drop across the unit, the electrical load, or the secondary fluid the rating uses. Those four gaps make the megawatt figure hard to compare with a rival quoted at a named approach. Ask for a selection at the site's own facility-water temperature and approach, the hydraulic curve, and which parts can be exchanged while the row stays live.

Who makes the DCX Enterprise ECDU 1380/2600?

DCX Liquid Cooling makes it. We file it under coolant distribution units, and its status is available.

What are the key specifications for the DCX Enterprise ECDU 1380/2600?

Footprint: 600 mm or 800 mm wide, standard rack depth; Redundancy: N+1 pumps, power supplies and controls; Coolant flow: Up to 3,333 liters per minute, single pump. These figures come from the supplier. Before comparing two products, restate both at your own water temperatures, flow, pressure, and redundancy, because a rating measured under favorable conditions will not hold on site.