Coolant distribution unit Product

Kelvion Centralised Coolant Distribution Unit

A centralised coolant distribution skid, delivered in 4 MW and 9 MW sizes for one 200 MW data center phase.

CDU9 MWcentralised skidhyperscale

Direct answer

What this record says

Kelvion Centralised Coolant Distribution Unit is a cooling product from Kelvion. The supplier publishes a capacity of Skids above 9 MW and above 4 MW as delivered, not yet reviewed as a normalized claim. Its lifecycle status is available. Last reviewed Sept. 4, 2026 against 1 source.

1 sourceReviewed Sept. 4, 2026
Manufacturer
Kelvion
Rated capacity
Skids above 9 MW and above 4 MW as deliveredNo duty point stated
Total flow
Not recorded
Status
Available

Product brief

What the record shows

Kelvion approaches coolant distribution as engineered plant rather than a catalogue model, so its published evidence is a delivery rather than a datasheet. For the first phase of a large artificial-intelligence campus in the United States, rated at more than 200 megawatts, Kelvion supplied six centralised coolant distribution skids: five above 9 megawatts each and one above 4 megawatts. Each skid consolidates plate heat exchangers, pumps, filtration and valve control into one assembly sited outside the data hall, which frees floor space and gives one place to monitor the liquid loop.

The same order included site-erected air fin coolers with a high-pressure fogging system for heat rejection, so the liquid loop and the rejection plant came from one supplier. Kelvion states the order value at more than 40 million dollars and does not name the customer. Because these are engineered skids, no approach temperature, flow rate, footprint or electrical load is published, and the megawatt figures describe what was delivered to one site rather than a rating a second buyer can order.

Treat this record as evidence of capability at scale, not as a specification. A buyer should expect a selection exercise from its own facility-water temperatures, approach and flow, and should ask which parts of the skid can be serviced without draining the hall it feeds.

Capacity figures are supplier-reported unless the source says otherwise. Compare products at the same temperatures, flow, pressure, and redundancy state.

SpecificationSupplier-stated
Configuration
Centralised skid sited outside the data hallSupplier wording, not yet normalized
Rated capacity
Skids above 9 MW and above 4 MW as deliveredSupplier wording, not yet normalized
Delivered scope
Six skids for a phase rated above 200 MWSupplier wording, not yet normalized
Stated order value
More than 40 million dollarsSupplier wording, not yet normalized
Integrated components
Plate heat exchangers, pumps, filtration, valve controlSupplier wording, not yet normalized
Paired heat rejection
Site-erected air fin coolers with high-pressure foggingSupplier wording, not yet normalized
Manufacturer
Kelvion

Connected records

Compatible architecture

Connected records

Equipment category

Evidence ledger

Sources and evidence

The links below show where the factual claims came from. Supplier specifications remain supplier-reported unless the record names independent operating evidence.

  1. 01
Record information
Record ID
DCC / PROD / KELVION-CCDU
Record reviewed
Sept. 4, 2026
Record first published
Sept. 4, 2026
External sources
1
Search visibility
Offered to search engines

Required fields this record has not addressed yet, most important first:

  • Rating conditions
  • Total coolant flow
  • Facility-water supply and return
  • Technology-water temperature
  • Public deployment evidence
  • Pressure or head
  • Redundancy
  • Fluid compatibility
  • Dimensions
  • Deployment format

Decide between

Comparable products

The same equipment category from other manufacturers, most-evidenced first.

View all products

Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.

Direct answers

Frequently asked questions

Direct answers drawn from the record, its comparison fields, and the evidence linked below.

What is the Kelvion Centralised Coolant Distribution Unit?

Kelvion approaches coolant distribution as engineered plant rather than a catalogue model, so its published evidence is a delivery rather than a datasheet. For the first phase of a large artificial-intelligence campus in the United States, rated at more than 200 megawatts, Kelvion supplied six centralised coolant distribution skids: five above 9 megawatts each and one above 4 megawatts. Each skid consolidates plate heat exchangers, pumps, filtration and valve control into one assembly sited outside the data hall, which frees floor space and gives one place to monitor the liquid loop. The same order included site-erected air fin coolers with a high-pressure fogging system for heat rejection, so the liquid loop and the rejection plant came from one supplier. Kelvion states the order value at more than 40 million dollars and does not name the customer. Because these are engineered skids, no approach temperature, flow rate, footprint or electrical load is published, and the megawatt figures describe what was delivered to one site rather than a rating a second buyer can order. Treat this record as evidence of capability at scale, not as a specification. A buyer should expect a selection exercise from its own facility-water temperatures, approach and flow, and should ask which parts of the skid can be serviced without draining the hall it feeds.

Who makes the Kelvion Centralised Coolant Distribution Unit?

Kelvion makes it. We file it under coolant distribution units, and its status is available.

What are the key specifications for the Kelvion Centralised Coolant Distribution Unit?

Configuration: Centralised skid sited outside the data hall; Rated capacity: Skids above 9 MW and above 4 MW as delivered; Delivered scope: Six skids for a phase rated above 200 MW. These figures come from the supplier. Before comparing two products, restate both at your own water temperatures, flow, pressure, and redundancy, because a rating measured under favorable conditions will not hold on site.