Coolant distribution unit Product

STULZ CyberCool CMU

STULZ's first liquid cooling product, a coolant distribution unit rated from 345 to 1,380 kW at 32°C facility water.

CDU1,380 kWwarm waterfree cooling

Direct answer

What this record says

STULZ CyberCool CMU is a cooling product from STULZ. The supplier publishes a capacity of 345 kW to 1,380 kW, not yet reviewed as a normalized claim. Its lifecycle status is available. Last reviewed Sept. 4, 2026 against 1 source.

1 sourceReviewed Sept. 4, 2026
Manufacturer
STULZ
Rated capacity
345 kW to 1,380 kWNo duty point stated
Total flow
Not recorded
Status
Available

Product brief

What the record shows

The CyberCool CMU is STULZ's first liquid cooling product, from a company known for room air conditioning. The unit isolates facility water from the technology cooling loop and controls the temperature and flow delivered to the racks. STULZ publishes a rated heat exchange of 345 to 1,380 kW across two model sizes, at a rated facility-water supply of 32 degrees Celsius and a technology loop supply of 36 degrees.

Those two temperatures are the useful part of the rating, because a capacity quoted without them cannot be compared. The 32 degree figure also places the unit in the warm-water classes, so a chiller with free cooling can run in economiser mode for most of the year in temperate climates. The smaller cabinet is 600 mm wide and weighs 460 kg; the larger is 900 mm wide and weighs 900 kg.

Both are 1,200 mm deep and 2,090 mm tall. Components can be reached from the front or the rear and carry shut-off valves on both sides for maintenance. STULZ does not publish the approach temperature, the secondary flow rate, the pressure drop, or the electrical load in this material.

Ask for the flow and approach at the site's own water temperature, and for the capacity with one pump out of service.

Capacity figures are supplier-reported unless the source says otherwise. Compare products at the same temperatures, flow, pressure, and redundancy state.

SpecificationSupplier-stated
Models
SCR4402 W and SCR14103 WSupplier wording, not yet normalized
Weight
460 kg or 900 kgSupplier wording, not yet normalized
Footprint
600 or 900 mm wide, 1,200 mm deep, 2,090 mm tallSupplier wording, not yet normalized
Water classes
ASHRAE W32 to W+Supplier wording, not yet normalized
Rated capacity
345 kW to 1,380 kWSupplier wording, not yet normalized
Facility water supply
32°C ratedSupplier wording, not yet normalized
Technology loop supply
36°C ratedSupplier wording, not yet normalized
Manufacturer
STULZ

Connected records

Compatible architecture

Connected records

Equipment category

Evidence ledger

Sources and evidence

The links below show where the factual claims came from. Supplier specifications remain supplier-reported unless the record names independent operating evidence.

  1. 01
Record information
Record ID
DCC / PROD / STULZ-CYBERC
Record reviewed
Sept. 4, 2026
Record first published
Sept. 4, 2026
External sources
1
Search visibility
Offered to search engines

Required fields this record has not addressed yet, most important first:

  • Rating conditions
  • Total coolant flow
  • Technology-water temperature
  • Public deployment evidence
  • Pressure or head
  • Redundancy
  • Fluid compatibility
  • Deployment format

Decide between

Comparable products

The same equipment category from other manufacturers, most-evidenced first.

View all products

Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.

Direct answers

Frequently asked questions

Direct answers drawn from the record, its comparison fields, and the evidence linked below.

What is the STULZ CyberCool CMU?

The CyberCool CMU is STULZ's first liquid cooling product, from a company known for room air conditioning. The unit isolates facility water from the technology cooling loop and controls the temperature and flow delivered to the racks. STULZ publishes a rated heat exchange of 345 to 1,380 kW across two model sizes, at a rated facility-water supply of 32 degrees Celsius and a technology loop supply of 36 degrees. Those two temperatures are the useful part of the rating, because a capacity quoted without them cannot be compared. The 32 degree figure also places the unit in the warm-water classes, so a chiller with free cooling can run in economiser mode for most of the year in temperate climates. The smaller cabinet is 600 mm wide and weighs 460 kg; the larger is 900 mm wide and weighs 900 kg. Both are 1,200 mm deep and 2,090 mm tall. Components can be reached from the front or the rear and carry shut-off valves on both sides for maintenance. STULZ does not publish the approach temperature, the secondary flow rate, the pressure drop, or the electrical load in this material. Ask for the flow and approach at the site's own water temperature, and for the capacity with one pump out of service.

Who makes the STULZ CyberCool CMU?

STULZ makes it. We file it under coolant distribution units, and its status is available.

What are the key specifications for the STULZ CyberCool CMU?

Models: SCR4402 W and SCR14103 W; Weight: 460 kg or 900 kg; Footprint: 600 or 900 mm wide, 1,200 mm deep, 2,090 mm tall. These figures come from the supplier. Before comparing two products, restate both at your own water temperatures, flow, pressure, and redundancy, because a rating measured under favorable conditions will not hold on site.