Two-phase cooling sidecar Product

ZutaCore HyperCool 240kW Sidecar

A closed-loop, facility-water-free sidecar designed to cool up to two 120 kW racks in existing air-cooled facilities.

sidecar240 kWtwo phasewaterless

Direct answer

What this record says

ZutaCore HyperCool 240kW Sidecar is a cooling product from ZutaCore. It is rated at 240 kW, with no duty point stated alongside the figure. Its lifecycle status is announced. Last reviewed Aug. 9, 2026 against 1 source.

1 sourceReviewed Aug. 9, 2026
Manufacturer
ZutaCore
Rated capacity
240 kWNo duty point stated
Total flow
Not recorded
Status
Announced

Product brief

What the record shows

The HyperCool 240kW Sidecar is a liquid-to-air heat-rejection unit for ZutaCore's two-phase direct-to-chip system. Dielectric fluid boils at processor cold plates, then the sidecar condenses the vapor and rejects the heat into data-hall air. This avoids a facility-water connection in the white space, which can suit an existing air-cooled building.

It does not make the heat disappear: room air handlers and the central plant must still remove as much as 240 kW of added sensible heat from the sidecar exhaust. ZutaCore says one unit can support two 120 kW racks or four 60 kW racks. It also reports 0.3 liters per minute per kilowatt, N+1 hot-swappable pumps and fans, remote monitoring, and data-center-infrastructure-management integration.

Those are announced design claims; the August 2025 source does not provide an independent test report, full fan curve, acoustic data, dimensions, weight, electrical demand, or performance versus room-air temperature. Compare it with a water-connected coolant distribution unit only after including sidecar fan energy and the facility energy needed to cool its discharge air. Confirm exact processor and server approval, cold-plate and refrigerant compatibility, hose routing, rack spacing, fire and refrigerant requirements, and available air-cooling headroom.

Ask what capacity remains during a fan or pump change, how hot air is contained, and whether controls can coordinate with the room system. Availability, lead time, warranty boundaries, and field references also need written confirmation because the source describes an announced product.

Capacity figures are supplier-reported unless the source says otherwise. Compare products at the same temperatures, flow, pressure, and redundancy state.

Specification5 reviewed claims
Rated capacity
240 kWCapacity: “Up to 240 kWSupplier reported · ZutaCore · reviewed 2026-09-04
Facility water requirement
Not required in white spaceSupplier reported · ZutaCore · reviewed 2026-09-04
Rack support
Two 120 kW or four 60 kW racksSupplier reported · ZutaCore · reviewed 2026-09-04
Serviceability
Hot-swappable componentsSupplier reported · ZutaCore · reviewed 2026-09-04
Lifecycle
AnnouncedSupplier reported · ZutaCore · reviewed 2026-09-04
Manufacturer
ZutaCore

Connected records

Compatible architecture

Connected records

Equipment category

Evidence ledger

Sources and evidence

The links below show where the factual claims came from. Supplier specifications remain supplier-reported unless the record names independent operating evidence.

  1. 01
Record information
Record ID
DCC / PROD / ZUTACORE-HYP
Record reviewed
Aug. 9, 2026
Latest claim reviewed
Sept. 4, 2026
Newest source published
Aug. 5, 2025
Record first published
Aug. 9, 2026
External sources
1
Search visibility
Offered to search engines

Required fields this record has not addressed yet, most important first:

  • Rating conditions
  • Total coolant flow
  • Technology-water temperature
  • Public deployment evidence
  • Pressure or head
  • Redundancy
  • Fluid compatibility
  • Dimensions

Decide between

Comparable products

The same equipment category from other manufacturers, most-evidenced first.

View all products

Add two or more, then open the comparison to see every stated claim, its duty point, and its source side by side.

Direct answers

Frequently asked questions

Direct answers drawn from the record, its comparison fields, and the evidence linked below.

What is the ZutaCore HyperCool 240kW Sidecar?

The HyperCool 240kW Sidecar is a liquid-to-air heat-rejection unit for ZutaCore's two-phase direct-to-chip system. Dielectric fluid boils at processor cold plates, then the sidecar condenses the vapor and rejects the heat into data-hall air. This avoids a facility-water connection in the white space, which can suit an existing air-cooled building. It does not make the heat disappear: room air handlers and the central plant must still remove as much as 240 kW of added sensible heat from the sidecar exhaust. ZutaCore says one unit can support two 120 kW racks or four 60 kW racks. It also reports 0.3 liters per minute per kilowatt, N+1 hot-swappable pumps and fans, remote monitoring, and data-center-infrastructure-management integration. Those are announced design claims; the August 2025 source does not provide an independent test report, full fan curve, acoustic data, dimensions, weight, electrical demand, or performance versus room-air temperature. Compare it with a water-connected coolant distribution unit only after including sidecar fan energy and the facility energy needed to cool its discharge air. Confirm exact processor and server approval, cold-plate and refrigerant compatibility, hose routing, rack spacing, fire and refrigerant requirements, and available air-cooling headroom. Ask what capacity remains during a fan or pump change, how hot air is contained, and whether controls can coordinate with the room system. Availability, lead time, warranty boundaries, and field references also need written confirmation because the source describes an announced product.

Who makes the ZutaCore HyperCool 240kW Sidecar?

ZutaCore makes it. We file it under coolant distribution units, and its status is announced.

What are the key specifications for the ZutaCore HyperCool 240kW Sidecar?

Capacity: Up to 240 kW; Rack support: Two 120 kW or four 60 kW racks; Facility water: Not required in white space. These figures come from the supplier. Before comparing two products, restate both at your own water temperatures, flow, pressure, and redundancy, because a rating measured under favorable conditions will not hold on site.