Regional cooling market • Market
United States data center cooling market
More tracked suppliers and projects than anywhere else, covering hyperscale campuses, AI clusters, research computing, and retrofits.
Direct answer
What this record says
United States data center cooling market is a data-center market this database tracks cooling activity in. It covers 4 recorded deployments. Last reviewed Aug. 9, 2026 against 2 sources.
- Country
- United States
- Region
- Not recorded
- Deployments
- 4 deployments
Market brief
Why cooling is different here
The United States is not one cooling market. It is a collection of utility territories and local approval systems with very different weather, water, and construction conditions. A national supplier list is useful for finding firms with manufacturing and service reach.
It is not enough to qualify a project. The first market decision is power: where a large load can connect, when transmission work will finish, and which operating requirements the grid imposes. Cooling comes next because the chosen supply temperature and local hourly weather determine whether heat can be rejected dry, with evaporation, or with mechanical refrigeration.
The Department of Energy's design guidance favors warm information-technology temperatures, heat reuse where practical, and dry rejection where the climate permits. That is a method, not a promise that one plant works in every state. Water exposure also changes locally.
Withdrawal, discharge, drought planning, and public scrutiny can make an efficient evaporative system harder to approve than a less energy-efficient dry design. Supply chains are broad but uneven. The country has specialist cold-plate, immersion, and coolant-distribution firms as well as global plant vendors, yet factory location does not prove local commissioning staff or spares.
Buyers should ask for service coverage at the exact campus. The tracked evidence ranges from operating research and energy-company immersion systems in Texas to an Ashburn demonstration and an anonymous multi-site equipment order. These are not comparable forms of proof.
A procurement shortlist should distinguish named operating references from pilots and supplier-reported backlog. For site selection, compare utility milestones, summer design conditions, annual water, refrigerant and fire rules, labor, service response, and the residual air load. The country page is therefore a routing layer; the decision belongs at state, utility, and site level.
The scale of announced AI campuses is pushing demand toward multi-megawatt distribution, plants that can run on warm water, and designs that can be repeated rather than engineered from scratch.
Connected records
Companies connected to this market
Vertiv
Sells almost every part of a data center's cooling chain, from the coolant distribution unit at the rack to the chillers outside.
CoolIT Systems
A liquid cooling specialist that makes the parts inside the rack: cold plates, manifolds, and the units that feed them.
Motivair
A liquid cooling specialist for supercomputing sites, supplying both the rack equipment and the chillers behind it.
LiquidStack
Makes both kinds of liquid cooling: the distribution equipment for cold plates, and tanks for immersion.
GRC
One of the longest-established immersion cooling companies, supplying the tanks, the fluid, and the controls together.
Accelsius
Two-phase cold-plate cooling, sold as rack and multi-rack systems under the NeuCool name.
Connected records
Tracked projects and contracts
LiquidStack 300 MW U.S. multi-site order
An American data center operator, not named, ordered 300 MW worth of LiquidStack's one-megawatt coolant distribution units for several AI sites.
TACC Lonestar6 immersion cooling
The Texas Advanced Computing Center uses GRC ICEraQ Series 10 immersion systems for part of its Lonestar6 supercomputer.
Shell Skybox Houston immersion cluster
Shell runs a 1.2 MW Penguin Solutions high-performance computing cluster in GRC immersion tanks at the Skybox Houston One facility.
Equinix Ashburn NeuCool deployment
Accelsius deployed its NeuCool IR80 two-phase direct-to-chip system at Equinix's DC15 Co-Innovation Facility in Ashburn.
Evidence ledger
Sources and evidence
The links below show where the factual claims came from. Supplier specifications remain supplier-reported unless the record names independent operating evidence.
- 01DataCenterChill deployment and company index
DataCenterChill
- 02Best Practices Guide for Energy-Efficient Data Center Design
U.S. Department of Energy · Jul 1, 2024