Product database
Compare named cooling products using published specifications, duty-condition caveats, compatibility questions, and the original supplier evidence.
Use this section to decide
What duty point and redundancy state sit behind the headline capacity?
Which servers, fluids, temperatures, and facility interfaces are supported?
What has the supplier not disclosed that must be resolved before a bid?
Featured records first, then the section's own editorial order.
An in-rack two-phase direct-to-chip cooling system demonstrated in co-innovation and high-density data-center environments.
Supplier reported5 of 12 required fields addressedReviewed Aug. 9, 2026
A row-sized coolant distribution unit rated at 2 MW, in a cabinet about 750 by 1200 mm.
Supplier reported5 of 12 required fields addressed
Project sourcing
Tell us the capacity, location, and timing once. We'll reply within one working day with suppliers that fit. It is free for buyers.
Get a supplier shortlistA coolant distribution platform built from blocks under one set of controls, tested in combinations up to 14 MW.
Supplier reported2 of 12 required fields addressedReviewed Aug. 9, 2026
A 250 kW in-row, multi-rack unit for the NeuCool two-phase direct-to-chip platform.
Supplier reported3 of 12 required fields addressedReviewed Aug. 9, 2026
An in-row coolant distribution unit rated at 2 MW with a 3°C approach, built to the fifth-generation Project Deschutes shape.
Supplier reported8 of 12 required fields addressedReviewed Sept. 4, 2026
A coolant distribution unit rated at 1,350 kW with a 4°C approach, offered with a heat exchanger that narrows the approach to 2°C.
Supplier reported6 of 12 required fields addressedReviewed Sept. 4, 2026
A coolant distribution unit that holds the server loop below atmospheric pressure, rated at 300 kW with a 7°C approach.
Supplier reported7 of 12 required fields addressedReviewed Sept. 4, 2026
A coolant distribution unit in 400 kW, 1,000 kW and 2,000 kW sizes, with an approach as narrow as 2 K and skids beyond 10 MW.
Supplier reported3 of 12 required fields addressedReviewed Sept. 4, 2026
A rack-format coolant distribution unit stated at 1.38 to 2.6 MW, with a single pump reaching 3,333 liters per minute.
Supplier reported7 of 12 required fields addressedReviewed Sept. 4, 2026
A liquid-to-liquid coolant distribution unit rated at 1,000 kW with a 5°C approach and 1,000 liters per minute in the server loop.
Supplier reported7 of 12 required fields addressedReviewed Sept. 4, 2026
A centralised coolant distribution skid, delivered in 4 MW and 9 MW sizes for one 200 MW data center phase.
Supplier reported2 of 12 required fields addressedReviewed Sept. 4, 2026
A high-capacity CDU used in direct-to-chip and hybrid liquid-cooling architectures.
Supplier reported4 of 12 required fields addressedReviewed Aug. 9, 2026
A coolant distribution unit rated at 600 kW with a 4°C approach at 600 liters per minute, in a 900 mm cabinet.
Supplier reported6 of 12 required fields addressedReviewed Sept. 4, 2026
A coolant distribution unit stated above 800 kW at a 6 K approach, using magnetically coupled pumps with no shaft seal to leak.
Supplier reported7 of 12 required fields addressedReviewed Sept. 4, 2026
A liquid-to-liquid coolant distribution unit for an Open Rack v3 footprint, stated at 1,000 kW at 4 K and 1,500 kW at 6 K.
Supplier reported6 of 12 required fields addressedReviewed Sept. 4, 2026
STULZ's first liquid cooling product, a coolant distribution unit rated from 345 to 1,380 kW at 32°C facility water.
Supplier reported4 of 12 required fields addressedReviewed Sept. 4, 2026
A 4U in-rack coolant distribution unit rated to 250 kW on water as warm as 45°C, part of the DLC-2 stack.
Supplier reported5 of 12 required fields addressedReviewed Sept. 4, 2026
A coolant distribution unit that transfers heat between two water loops, rated at about 1.35 MW.
Supplier reported2 of 12 required fields addressedReviewed Aug. 9, 2026