Compare named cooling products using published specifications, duty-condition caveats, compatibility questions, and the original supplier evidence.
Use this section to decide
What duty point and redundancy state sit behind the headline capacity?
Which servers, fluids, temperatures, and facility interfaces are supported?
What has the supplier not disclosed that must be resolved before a bid?
Featured records first, then the section's own editorial order.
| Record | Manufacturer | Category | Rated capacity | Rating conditions | Total flow | Loop | Scale | Fluid | Redundancy | Lifecycle | Deployment evidence | Fields addressed | Evidence | Sources | Reviewed | Comparison |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Accelsius NeuCool IR80 | Accelsius | Coolant Distribution Units | 80 kW | Not stated | Not stated | Two-phase direct-to-chip | In-rack | Non-conductive dielectric | Not stated | Available | Equinix Ashburn CIF |
Project sourcing
Tell us the capacity, location, and timing once. We'll reply within one working day with suppliers that fit. It is free for buyers.
Get a supplier shortlist| Supplier reported |
| 2 |
| CoolIT CHx2000 | CoolIT Systems | Coolant Distribution Units | 2,000 kW | Not stated | Not stated | Not stated | Row based | Not stated | Not stated | Available | Not stated | 5/12 | Supplier reported | 1 |
|---|
| LiquidStack GigaModular CDU | LiquidStack | Coolant Distribution Units | 2,500 kW | Not stated | Not stated | Pay as you grow | Not stated | Not stated | Not stated | Available | Not stated | 2/12 | Supplier reported | 1 |
|---|
| Accelsius MR250 | Accelsius | Coolant Distribution Units | 250 kW | Not stated | Not stated | Two phase | In-row, multi-rack | Not stated | Not stated | Available | Not stated | 3/12 | Supplier reported | 1 |
|---|
| Airedale by Modine TurboChill DCS | Modine | Chillers | 1,850 kW nominal gross, model TCC14R28K | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| Alfa Laval Cooling Pod | Alfa Laval | Dry Coolers | 500 kW or 1,000 kW | Not stated | Not stated | Dry cooler only; dual loop with gasketed plate; dual loop with 4–10 brazed plate units | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| Armstrong 4300 Vertical In-Line | Armstrong Fluid Technology | Pumps | Not stated | Not stated | Not stated | Not stated | Not stated | Water or glycol based | Not stated | Available | Not stated | 3/8 | Supplier reported | 1 |
|---|
| Armstrong 4380 Vertical In-Line | Armstrong Fluid Technology | Pumps | Not stated | Not stated | Not stated | Not stated | Not stated | Water or glycol based | Not stated | Available | Not stated | 3/8 | Supplier reported | 1 |
|---|
| Asperitas Direct Forced Convection tank | Asperitas | Immersion Tanks | 60 kW per tank | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Independently reported | 2 |
|---|
| BAC HXV Hybrid Cooler | Baltimore Aircoil Company | Cooling Towers | Up to 396 tons | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 1 |
|---|
| BAC TrilliumSeries Dry Cooler | Baltimore Aircoil Company | Dry Coolers | Not publicly disclosed | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| Belimo EP200H EPIV | Belimo | Valves | Not stated | Not stated | Not stated | Not stated | Not stated | Chilled or hot water, up to 60% glycol | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| Belimo EV200H Energy Valve | Belimo | Valves | Not stated | Not stated | Not stated | Not stated | Not stated | Chilled or hot water, up to 60% glycol | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| Beyond by Valvoline HPC Heat Transfer Fluid PG25 Advanced | Valvoline Global Operations | Coolants | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| Beyond by Valvoline HPC Immersion Heat Transfer Fluid DE1 | Valvoline Global Operations | Coolants | Not stated | Not stated | Not stated | Not stated | Not stated | Not disclosed on the cited public product page | Not stated | Available | Not stated | 4/8 | Supplier reported | 2 |
|---|
| Boyd ROL4000 | Boyd | Coolant Distribution Units | 2 MW at 3°C approach | Not stated | 1,890 liters per minute (500 gallons per minute) | Not stated | Not stated | 1,890 liters per minute (500 gallons per minute) | Seal-less, N+1, redundant power feed per circuit | Available | Not stated | 8/12 | Supplier reported | 1 |
|---|
| Carrier CDU 65LL | Carrier | Coolant Distribution Units | 1,350 kW at 4°C approach | Not stated | 0 to 1,650 liters per minute at 350 kPa, single pump | Not stated | Not stated | 0 to 1,650 liters per minute at 350 kPa, single pump | Dual pumps N+1, sensor redundancy, in-unit UPS | Available | Not stated | 6/12 | Supplier reported | 2 |
|---|
| Castrol ON Immersion Cooling Fluid DC 15 | Castrol | Coolants | Not stated | Not stated | Not stated | Not stated | Not stated | Synthetic hydrocarbon dielectric coolant | Not stated | Available | Not stated | 4/8 | Supplier reported | 1 |
|---|
| Castrol ON Immersion Cooling Fluid DC 20 | Castrol | Coolants | Not stated | Not stated | Not stated | Not stated | Not stated | Synthetic hydrocarbon dielectric coolant | Not stated | Available | Not stated | 4/8 | Supplier reported | 2 |
|---|
| Chilldyne CF-CDU300 | Chilldyne | Coolant Distribution Units | 300 kW at 7°C approach | Not stated | Up to 300 liters per minute | Maximum 22 inHg of vacuum | Not stated | Water or water-glycol | Not stated | Available | Not stated | 7/12 | Supplier reported | 2 |
|---|
| CPC Everis UQD02 | CPC | Quick Disconnects | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 2/8 | Supplier reported | 1 |
|---|
| CPC Everis UQD08 and UQDB08 | CPC | Quick Disconnects | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 2/8 | Supplier reported | 1 |
|---|
| Daikin Coolant Distribution Unit | Daikin | Coolant Distribution Units | 400 kW, 1,000 kW or 2,000 kW | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/12 | Supplier reported | 2 |
|---|
| Danfoss Hansen UQD couplings | Danfoss | Quick Disconnects | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| DCX Enterprise ECDU 1380/2600 | DCX Liquid Cooling | Coolant Distribution Units | 1.38 MW to 2.6 MW | Not stated | Up to 3,333 liters per minute, single pump | Not stated | Not stated | Up to 3,333 liters per minute, single pump | N+1 pumps, power supplies and controls | Available | Not stated | 7/12 | Supplier reported | 1 |
|---|
| Delta GoCool-1000 | Delta Electronics | Coolant Distribution Units | 1,000 kW at 5°C approach; 750 kW at 4°C approach | Not stated | 1,000 liters per minute secondary; 1,200 primary | Not stated | Not stated | 25% propylene glycol | Not stated | Available | Not stated | 7/12 | Supplier reported | 1 |
|---|
| Ecolab 3D TRASAR Cooling Water Technology | Ecolab | Water Treatment | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 2/8 | Supplier reported | 2 |
|---|
| Ecolab 3D TRASAR Technology for Adiabatic Cooling | Ecolab | Controls | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 2/8 | Supplier reported | 1 |
|---|
| EVAPCO eco-Air APEX Dry Cooler | EVAPCO | Dry Coolers | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| EVAPCO eco-Air Double Stack Dry Cooler | EVAPCO | Dry Coolers | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 1 |
|---|
| GRC ICEraQ Series 10 | GRC | Immersion Tanks | Not stated | Not stated | Not stated | Single-phase immersion | Modular tank | Dielectric fluid | Not stated | Available | TACC Lonestar6 | 4/8 | Supplier reported | 2 |
|---|
| Grundfos KPVS | Grundfos | Pumps | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| Grundfos NBG 150-125-315/336 | Grundfos | Pumps | Not stated | Not stated | Not stated | NBG 150-125-315/336 | Not stated | Not stated | Not stated | Available | Not stated | 4/8 | Supplier reported | 2 |
|---|
| Güntner Flat VARIO Dry Cooler | Güntner | Dry Coolers | Not stated | Not stated | Not stated | Not publicly disclosed | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 1 |
|---|
| Güntner V-shape VARIO Dry Cooler | Güntner | Dry Coolers | 75–2,040 kW | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 1 |
|---|
| HPE ProLiant Compute XD685 with direct liquid cooling | HPE | Cold Plates | Not stated | Not stated | Not stated | Not stated | 5U modular, eight accelerators per node | Not stated | Not stated | Available | Not stated | 2/8 | Supplier reported | 2 |
|---|
| Iceotope KUL AI | Iceotope | Immersion Tanks | Not stated | Not stated | Not stated | Not stated | Not stated | Dielectric fluid | Not stated | Available | Not stated | 4/8 | Supplier reported | 2 |
|---|
| JetCool SmartPlate System for Dell PowerEdge R770 | JetCool | Cold Plates | Not stated | Not stated | Not stated | Not stated | Not stated | PG25 and water-based coolants | Not stated | Available | Not stated | 4/8 | Supplier reported | 2 |
|---|
| Kelvion Centralised Coolant Distribution Unit | Kelvion | Coolant Distribution Units | Skids above 9 MW and above 4 MW as delivered | Not stated | Not stated | Centralised skid sited outside the data hall | Not stated | Not stated | Not stated | Available | Not stated | 2/12 | Supplier reported | 1 |
|---|
| Kurita Korrodex | Kurita Water Industries | Water Treatment | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 1 |
|---|
| Kurita S.sensing MX | Kurita Water Industries | Controls | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 1 |
|---|
| Lenovo ThinkSystem N1380 Neptune enclosure | Lenovo | Manifolds | Up to 54 kW with four 15 kW stations | Not stated | 3.0 liters per minute per tray at 45°C; 35.2 per enclosure | Not stated | 13U in a 19-inch rack, eight compute trays | Treated water, not a glycol mixture | Not stated | Available | Not stated | 4/8 | Supplier reported | 2 |
|---|
| LiquidStack CDU-1MW | LiquidStack | Coolant Distribution Units | 1,000 kW | Not stated | Not stated | Not stated | High-capacity CDU | Not stated | Not stated | Available | Multi-site capable | 4/12 | Supplier reported | 1 |
|---|
| LITE-ON CL-LL-WCDU-6011 | LITE-ON | Coolant Distribution Units | 600 kW at 600 liters per minute, 4°C approach | Not stated | 600 liters per minute at 2.45 bar external differential | 7°C to 35°C | Not stated | Treated water or 25% propylene glycol | Not stated | Available | Not stated | 6/12 | Supplier reported | 1 |
|---|
| MEHITS i-FX-G01-DC-Z | Mitsubishi Electric Hydronics & IT Cooling Systems | Chillers | Not publicly disclosed | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 4/8 | Supplier reported | 1 |
|---|
| MEHITS TR2-FC-G04-Z | Mitsubishi Electric Hydronics & IT Cooling Systems | Chillers | 840–1,800 kW | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| MHI Thermal Systems ETI-Z | Mitsubishi Heavy Industries Thermal Systems | Chillers | 150–700 RT | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 3/8 | Supplier reported | 2 |
|---|
| MHI Thermal Systems GART-ZE/ZEI | Mitsubishi Heavy Industries Thermal Systems | Chillers | 300–5,000 RT | Not stated | Not stated | Not stated | Not stated | Not stated | Not stated | Available | Not stated | 4/8 | Supplier reported | 1 |
|---|